POLISCOPE

The public record

LIVEOAK (SUTTER COUNTY)Held · official record pendingPartial coverage

Water, Sewer, and Storm Drain Committee

Friday, April 1, 2022 · Government meeting record

The 30-second read

Record incomplete

Water, Sewer, and Storm Drain Committee

Why it matters

The official meeting record is available below. Item-level plain-language summaries are not available yet.

What happens next

The scheduled meeting date has passed. Minutes or an action agenda are not published in the records we hold.

This meeting date has passed and no official outcome record has been published yet. Nothing on this page is a decision.

Record text

No recording or transcript is held for this meeting.

Showing the first 60,000 of 2,452,486 characters. The full document is at the source.

LIVE OAK CITY COUNCIL AGENDA – APRIL 1, 2022 Page 1 The Committee may take up any agenda item at any time, regardless of the order listed. Action may be taken on any item on this agenda. Materials related to an item on this Agenda submitted to the Committee after distribution of the agenda packet are available for public inspection at City Hall, 9955 Live Oak Boulevard, Live Oak, during normal business hours. Such documents are also available on the City of Live Oak’s website at www.liveoakcity.org, subject to staff’s availability to post the documents before the meeting. In compliance with the Americans with Disabilities Act, the meeting room is wheelchair accessible and disabled parking is available. If you have a disability and need disability-related modifications or accommodations to participate in this meeting, please contact the City Clerk’s office at (530) 695-2112 x107. Requests must be made at least 24 hours in advance. Pursuant to Governor Newsom’s Executive Orders N-25-20 and N-29-20, members of the Water, Sewer, and Storm Drain Committee or staff may participate in this meeting via a teleconference. In the interest of the maintaining appropriate social distancing, members of the public are encouraged to participate in the meeting in the following ways: • Public Attendance: o Seating is available in the Council Chamber. Please participate via web conference or email of you are ill or have been exposed to COVID-19. • Remote Viewing: o Members of the public can access the Zoom webinar as follows: ▪ Join by Electronic Device: https://us02web.zoom.us/j/82319581813 ▪ Join by Phone: 1-669-900-6833 or 1-833-548-0282 (Toll Free) Webinar ID: 823 1958 1813 WATER, SEWER, AND STORM DRAIN COMMITTEE REGULAR MEETING AGENDA APRIL 1, 2022 3:00 PM MEETING LOCATION LIVE OAK COUNCIL CHAMBERS 9955 LIVE OAK BOULEVARD LIVE OAK, CALIFORNIA 95953 MEMBERS OF THE COMMITTEE LAKHVIR GHAG, COUNCILMEMBER AARON PALMER, CITY MANAGER

LIVE OAK CITY COUNCIL AGENDA – APRIL 1, 2022 Page 2 • Public Comment: Members of the public can submit general public comments, as well as comment on specific agenda items in the following ways: o Public Attendance: Members of the public who attend in person may make comments from the Council Chamber podium. o Live Remote Public Comment: Members of the public can submit a live remote public comment by: ▪ Joining the virtual Committee meeting via the link below. When public comment is opened, raise your virtual hand and be called upon to speak for up to 3 minutes. https://us02web.zoom.us/j/82319581813 ▪ Joining the virtual Committee meeting by calling the phone number below. When public comment is opened, dial *9 to raise your hand and be called upon to speak for up to 3 minutes. 1-669-900-6833 or 1-833-548-0282 (Toll Free) Webinar ID: 823 1958 1813 o Email Public Comment: Comments from the public on agenda items will be accepted until 1:00 pm on the date of the meeting, via email to the City Clerk at cmenchaca@liveoakcity.org, and read into the record during public comment. CALL TO ORDER ROLL CALL PUBLIC COMMENT Any person wishing to address the Committee may do so at this time. Comments will be limited to three minutes unless further time is specifically granted. BUSINESS ITEMS 1. Bid Package for the Construction of the P Street Pump Station Project UPDATES AND ANNOUNCEMENTS COMMITTEE MEMBER REPORTS / COMMENTS / REQUESTS ADJOURNMENT

PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 COVER SHEET G-00101 NTS BDW PX BDW PROJECT SITE N PROJECT SITE GILLESPIE CIR N ST ELM ST P ST Q ST DATE ST P ST CALIFORNIA ST SUTTER COUNTY, CALIFORNIA CITY OF LIVE OAK UPDATE AND MODIFICATION PROJECT "P" STREET LIFT STATION SOUTH BUTTE LINDA SUTTER MARYSVILLE YUBA CITY GRIDLEY FIR ST TIERRA BUENA LIVE OAK ELM ST N BROADWAY PENNINGTON RD Item 1

PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 DRAWING SHEET INDEX AND DESIGN CRITERIA G-00202 NTS BDW PX BDW INSTRUMENTATION SHEET INDEX DWG NO. DRAWING TITLE DESIGN CRITERIA ITEM UNIT VALUE PUMP TYPE -- SUBMERSIBLE PUMPS NO. 3 LEAD\LAG\STANDBY DESIGN FLOW (EA) GPM 1000 TOTAL DYNAMIC HEAD (EA) FT 55 HORSEPOWER (EA) HP 20 PUMP STATION RELIABLE CAPACITY GPM 2000 GENERAL SHEET INDEX DWG NO. DRAWING TITLE SHEET NO. G-001 COVER SHEET G-002 DRAWING SHEET INDEX AND DESIGN CRITERIA G-003 GENERAL NOTES AND SYMBOLS G-004 GENERAL ABBREVIATIONS SURVEY SHEET INDEX DWG NO. DRAWING TITLE V-001 SURVEY CONTROL PLAN V-201 EXISTING CONDITIONS TOPOGRAPHIC MAPPING V-202 UTILITY INVERT TABLE STRUCTURAL SHEET INDEX DWG NO. DRAWING TITLE CIVIL SHEET INDEX DWG NO. DRAWING TITLE MECHANICAL SHEET INDEX DWG NO. DRAWING TITLE ELECTRICAL SHEET INDEX DWG NO. DRAWING TITLE GC-001 CIVIL DETAILS 1 GC-002 CIVIL DETAILS 2 GC-003 CIVIL DETAILS 3 GC-004 CIVIL DETAILS 4 GC-005 CIVIL DETAILS 5 GC-006 CIVIL DETAILS 6 GC-007 CIVIL DETAILS 7 - EROSION AND SEDIMENT CONTROL CD-101 SITE DEMOLITION PLAN CD-102 ELECTRICAL DEMOLITION CD-201 FLOW DIVERSION PLAN 1 CD-202 FLOW DIVERSION PLAN 2 CD-203 FLOW DIVERSION PLAN 3 CD-204 FLOW DIVERSION PLAN 4 CD-205 FLOW DIVERSION PLAN 5 CD-206 FLOW DIVERSION PLAN 6 CD-207 FLOW DIVERSION PLAN 7 CD-208 FLOW DIVERSION PLAN 8 C-001 EXISTING SITE, STAGING, ACCESS PLAN, & BMPs C-002 CIVIL SITE PLAN C-003 YARD PIPING PLAN C-004 YARD PIPING STATIONING PLAN C-005 PAVING AND GRADING C-101 EXISTING WET WELL & JUNCTION STRUCTURE PLAN C-102 EXISTING WET WELL & JUNCTION STRUCTURE SECTIONS C-201 PIPING PROFILES 1 C-202 PIPING PROFILES 2 C-203 PIPING PROFILES 3 S-001 STRUCTURAL NOTES S-002 STRUCTURAL NOTES S-003 STRUCTURAL NOTES S-101 ELECTRICAL & CONTROL BUILDING MODIFICATIONS S-102 METER AND VALVE VAULTS PLANS & SECTIONS S-103 WET WELL PLANS S-104 WET WELL SECTIONS S-105 PERIMETER CMU WALL S-106 EQUIPMENT FOUNDATIONS M-001 TYPICAL MECHANICAL DETAILS 1 M-002 TYPICAL MECHANICAL DETAILS 2 M-101 WET WELL, VALVE VAULT, AND FLOW METER VAULT PLAN M-102 ODOR CONTROL SYSTEM M-201 WET WELL, VALVE VAULT, AND FLOW METER VAULT SECTIONS E-001 ELECTRICAL ABBREVIATIONS & GENERAL NOTES E-002 ELECTRICAL SYMBOLS E-003 ONE-LINE DIAGRAM & LOAD CALCULATIONS E-004 MCC & CONTROL PANEL ELEVATIONS E-020 FVNR MOTOR CONTROL DIAGRAM E-030 TYPICAL ELECTRICAL DETAILS 1 E-031 TYPICAL ELECTRICAL DETAILS 2 E-100 ELECTRICAL SITE PLAN E-101 BUILDING POWER PLAN E-102 BUILDING GROUNDING & LIGHTING PLAN E-103 CONDUIT & CONDUCTOR SCHEDULE, INSTRUMENT INDEX I-001 INSTRUMENT SYMBOLS & ABBREVIATIONS I-002 SYSTEM ARCHITECTURE BLOCK DIAGRAM I-010 TYPICAL CONTROL PANEL ELEVATION I-011 TYPICAL CONTROL PANEL ELEMENTARY DIAGRAM I-020 EXAMPLE INTERCONNECT DRAWING I-021 EXAMPLE AI MODULE LOOP DIAGRAM I-022 EXAMPLE AO MODULE LOOP DIAGRAM I-023 EXAMPLE DI MODULE LOOP DIAGRAM I-024 EXAMPLE DO MODULE LOOP DIAGRAM I-030 INSTRUMENTATION DETAILS I-100 LIFT STATION P&ID I-101 AUXILIARY SYSTEMS P&ID M-003 TYPICAL MECHANICAL DETAILS 3

PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 GENERAL NOTES AND SYMBOLS 03 G-003 NTSBDW PX BDW GENERAL NOTES (CIVIL): 1. ALL NEW IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS AND SPECIFICATIONS, AND THE LATEST EDITION OF CITY OF LIVE OAK STANDARD SPECIFICATIONS AND PLANS UON. 2. THE INTENT IS THAT THESE PLANS REQUIRE ALL LABOR AND MATERIALS (EXCEPT AS SPECIFIED IN THE SPECIFICATIONS) NECESSARY AND PROPER TO EXECUTE THE WORK CONTEMPLATED AND THAT THE WORK BE COMPLETED IN ACCORDANCE WITH THEIR TRUE INTENT AND PURPOSE. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY REGARDING ANY DISCREPANCIES AND AMBIGUITIES WHICH MAY EXIST IN THE PLANS OR SPECIFICATIONS. 3. THE TYPES, LOCATION, SIZES AND/OR DEPTHS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THESE PLANS WERE OBTAINED BY THE DESIGN ENGINEER FROM "OUTSIDE SOURCES," BELIEVED TO BE RELIABLE. HOWEVER, THE CONTRACTOR IS CAUTIONED THAT ONLY ACTUAL EXCAVATION WILL REVEAL THE TYPES, EXTENT, SIZES, LOCATION, AND DEPTHS OF SUCH UNDERGROUND UTILITIES. DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF ITS DELINEATION OF SUCH UNDERGROUND UTILITIES WHICH MAY BE ENCOUNTERED BUT WHICH ARE NOT SHOWN ON THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE PHYSICAL LOCATION OF ALL EXISTING UNDERGROUND UTILITIES BY POTHOLING PRIOR TO CONSTRUCTION AND SHALL CONTACT THE RESPECTIVE UTILITY COMPANIES PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF ALL SUCH FACILITIES IN THE AREA OF CONSTRUCTION, AND SHALL NOTIFY UTILITY COMPANIES FORTY-EIGHT HOURS IN ADVANCE OF ANY CONSTRUCTION (UNDERGROUND SERVICE ALERT 1-800-227-2600). 5. THE CONTRACTOR'S ATTENTION IS DIRECTED TO SECTION 1540 (A)(1) OF THE CONSTRUCTION SAFETY ORDERS (TITLE 8 CALIFORNIA ADMINISTRATION CODE SECTION 1540), ISSUED BY THE OCCUPATIONAL SAFETY AND HEALTH STANDARDS BOARD PURSUANT TO THE CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH ACT OF 1973, AS AMENDED, WHICH STATES: 5.1. PRIOR TO OPENING AN EXCAVATION, EFFORT SHALL BE MADE TO DETERMINE WHETHER UNDERGROUND INSTALLATION: I.E., SEWER, WATER, FUEL, ELECTRIC LINES, ETC., WILL BE ENCOUNTERED AND, IF SO, WHERE SUCH UNDERGROUND INSTALLATIONS ARE LOCATED. WHEN THE EXCAVATION APPROACHES THE APPROXIMATE LOCATION OF SUCH AN INSTALLATION, THE EXACT LOCATION SHALL BE DETERMINED BY CAREFUL PROBING OR AND DIGGING; AND WHEN IT IS UNCOVERED, ADEQUATE PROTECTION SHALL BE PROVIDED FOR THE EXISTING INSTALLATION. ALL KNOWN OWNERS OF UNDERGROUND FACILITIES IN THE AREA CONCERNED SHALL BE ADVISED OF PROPOSED WORK AT LEAST 48 HOURS PRIOR TO THE START OF ACTUAL EXCAVATION. 6. THE CONTRACTOR SHALL PROVIDE SHORING, BRACING, SLOPING OR PROVISIONS TO PROTECT WORKERS FOR ALL AREAS TO BE EXCAVATED TO A DEPTH OF FIVE FEET OR MORE. SAID PROTECTION TO BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF LOCAL, STATE, AND FEDERAL REGULATIONS (CAL-OSHA, OSHA). 7. ASBESTOS CEMENT MATERIALS SHALL NOT BE USED IN THE CONSTRUCTION OF ANY FACILITIES WITHIN THIS PROJECT. IMMEDIATELY NOTIFY THE ENGINEER IF ASBESTOS CEMENT MATERIALS ARE FOUND. 8. DURING CONSTRUCTION THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF EXISTING FACILITIES. 9. THE CONTRACTOR IS RESPONSIBLE FOR REFERENCING EXISTING MONUMENTS AND/OR PROPERTY CORNER PRIOR TO COMMENCEMENT OF WORK. 10. UON CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS AND LICENSES REQUIRED FOR THE CONSTRUCTION AND COMPLETION OF PROJECT. 11. ALL WORK IN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE APPROVAL AND ACCEPTANCE OF THE CITY OF LIVE OAK. 12. CONTRACTOR SHALL COORDINATE THE REMOVAL AND/OR RELOCATION OF ALL EXISTING UTILITIES IF NEEDED WITH RESPECTIVE UTILITY COMPANIES. 13. THE CONTRACTOR SHALL ADJUST TO GRADE ALL FACILITIES (INCLUDING, BUT NOT LIMITED TO VALVE BOXES, PULL BOXES, MH RIM AND COVERS, METER BOXES) WITHIN THE LIMITS OF WORK AND/OR AS DIRECTED BY ENGINEER. THE FACILITIES SHALL BE ADJUSTED AS DIRECTED BY ENGINEER. 14. THE CONTRACTOR SHALL PROVIDE ALL LIGHTS, BARRICADES, SIGNS, FLAGMEN OR OTHER DEVICES NECESSARY FOR PUBLIC SAFETY. 15. CONTRACTOR SHALL DEMOLISH, EXCAVATE, REMOVE AND DISPOSE OF ANY EXISTING CONCRETE OR ASPHALT CONCRETE PAVING, CONCRETE CURB, GUTTER AND SIDEWALK AND DELETERIOUS MATERIAL AS REQUIRED TO CONSTRUCT THE CONTRACT WORK. ALL EXCESS MATERIAL GENERATED BY DEMOLITION, EXCAVATION AND GRADING SHALL BE DISPOSED OF BY THE CONTRACTOR UON. LEGEND: 16. CONTRACTOR AGREES THAT CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOBSITE CONDITIONS DURING THE COURSES OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE CITY, COUNTY AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE CITY OR THE ENGINEER. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY FIELD CHANGES MADE WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER OR THE ENGINEER. WATER & SANITARY SEWER IMPROVEMENT NOTES: 1. THE CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT, WHERE APPLICABLE, FOR ANY WORK DONE ON CITY OF LIVE OAK FACILITIES NOT SHOWN ON THE DRAWINGS. CONTRACTOR SHALL NOTIFY CITY 48 WORKING HOURS IN ADVANCE OF COMMENCING THE WORK OR AS REQUIRED BY SAID PERMIT. 2. THE CONTRACTOR SHALL OBTAIN A PERMIT AND METER FROM THE CITY OF LIVE OAK FOR ANY USE OF WATER FROM FIRE HYDRANTS AND PAY ALL FEES FOR PERMIT AND USAGE. CONTRACTOR SHALL ENSURE AIR GAP IS PROVIDED AT ALL TIMES. 3. ACTUAL CONNECTIONS TO EXISTING WATER LINES WILL NOT BE PERMITTED PRIOR TO THE COMPLETION OF DISINFECTION AND TESTING OF NEW WATER MAINS. ALL WATER VALVES TO BE OPERATED UNDER THE DIRECTION OF THE WATER DIVISION PERSONNEL ONLY. 4. ALL BURIED DUCTILE IRON PIPE, FITTINGS AND APPURTENANCES SHALL BE PROTECTED AGAINST CORROSION AS SET FORTH IN THE SPECIFICATIONS. 6. THE CONTRACTOR SHALL MAINTAIN A NEATLY MARKED SET OF FULL-SIZED AS-BUILT RECORD DRAWINGS UPDATED WEEKLY (AVAILABLE FOR CITY INSPECTION AT ALL TIMES) SHOWING THE FINAL LOCATION AND LAYOUT OF ALL STRUCTURES AND OTHER FACILITIES. WHERE NECESSARY, SUPPLEMENTAL DRAWINGS SHALL BE PREPARED AND SUBMITTED BY THE CONTRACTOR. 7. PRIOR TO ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THE ENGINEER ONE SET OF NEATLY MARKED AS-BUILT RECORD DRAWINGS. 8. THE DISCHARGE OF CHLORINATED WATER INTO THE STORM DRAIN SYSTEM IS PROHIBITED. THE DISCHARGE OF CHLORINATED WATER INTO SANITARY SEWER SYSTEM REQUIRES PRIOR APPROVAL FROM THE CITY. 9. DUST CONTROL SHALL BE PROVIDED AT ALL TIMES, AT THE CONTRACTOR'S EXPENSE, TO MINIMIZE ANY DUST NUISANCE AND SHALL BE IN ACCORDANCE WITH SECTION 10 OF CALTRANS STANDARD SPECIFICATIONS. 10. FINAL PAVEMENT WORK SHALL NOT OCCUR WITHIN THE ROAD RIGHT-OF-WAY PRIOR TO COMPLETION OF UTILITY RELOCATION WITHOUT SPECIFIC APPROVAL OF THE ENGINEER. 11. WHENEVER PAVEMENT IS BROKEN OR CUT IN THE INSTALLATION OF THE WORK COVERED BY THE SPECIFICATIONS, THE PAVEMENT SHALL BE REPLACED AFTER PROPER BACKFILLING WITH PAVEMENT MATERIALS EQUAL TO OR BETTER THAN THE MATERIALS USED IN THE ORIGINAL PAVING. 12. DRAINAGE FACILITIES SHALL BE MAINTAINED DURING PERIODS OF INCLEMENT WEATHER, AND RESTORED TO THEIR ORIGINAL CONDITIONS UPON COMPLETION OF THE WORK. 13. CONTRACTOR SHALL PROTECT ALL BENCHMARKS AND SURVEYED MONUMENTS DURING CONSTRUCTION. DAMAGED OR REMOVED MONUMENTS SHALL BE REPLACED, WITH THE SAME ORDER OF ACCURACY, AT THE CONTRACTOR'S EXPENSE. 14. PRIOR TO PLACEMENT OF ANY FINISH ASPHALT CONCRETE OR CONCRETE, THE CONTRACTOR SHALL VERIFY ALL FINISH GRADES AND SLOPES FOR COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT (ADA). 15. THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER FOR ALL TEMPORARY AND LONG-TERM MATERIAL STORAGE LOCATIONS AND ALL HAUL ROUTES. 16. UNLESS OTHERWISE SHOWN ON THE PLANS, ALL PIPES SHALL HAVE A MINIMUM COVER OF 36" FROM FINISH GRADE. 17. ALIGNMENT OF NEW PIPELINES AS SHOWN ON DRAWINGS ARE APPROXIMATE. CONTRACTOR IS RESPONSIBLE FOR FITTING ACTUAL ALIGNMENT OF PIPES TO CONFORM AS NEAR AS POSSIBLE TO DESIGN BY PROPER SELECTION AND PLACEMENT OF PIPE AND FITTINGS. THE NUMBER OF HIGH AND LOW POINTS IN PIPELINES SHALL NOT BE INCREASED FROM THE NUMBER PROVIDED FOR BY ELEVATIONS SHOWN. DEFLECTION OF PIPE JOINTS SHALL BE LIMITED TO VALUES RECOMMENDED BY MANUFACTURER. 18. A MINIMUM OF 6" OF CLEARANCE BETWEEN PIPE CROSSING UNDERGROUND SHALL BE MAINTAINED WHEN SHOWN ON DRAWINGS OR NOT. PROVIDE A STYROFOAM PAD (12" SQ. MIN) BETWEEN PIPES FOR ANY CLEARANCE LESS THAN 12". 19. PIPELINES SHALL SLOPE UNIFORMLY BETWEEN ELEVATIONS SHOWN ON PLANS AND PROFILES. ALL PIPE ELEVATIONS SHOWN REFERS TO INVERT UNLESS OTHERWISE NOTED. 20. ALL GRADING SHALL BE PERFORMED IN SUCH A MANNER AS TO COMPLY WITH THE STANDARDS ESTABLISHED BY THE PROJECT SPECIFICATIONS AND AGENCIES HAVING JURISDICTION FOR AIRBORNE PARTICULATES (DUST). NEW EXISTING DESCRIPTION NEW EXISTING DESCRIPTION NEW CONCRETE ASPHALT CONCRETE PAVING GRAVEL AGGREGATE BASE PEA GRAVEL DRAIN ROCK AGGREGATE SURFACE COURSE GROUND LINE EXISTING WALL OF STRUCTURE DETAIL OR SECTION INDICATOR NUMBER SHEET OR DRAWING NUMBER WHERE DETAIL APPEARS REVISION NUMBER SECTION INDICATOR LETTER GENERAL SHEET NOTE CONSTRUCTION INDICATOR NOTE PIPE SLOPE GUTTER SLOPE PAVING GRADE SLOPE DRAFTING CONVENTIONS: COORDINATE GEOMETRY NUMBER I.D. ELEVATION DESCRIPTION TESTING: 1. THE OWNER WILL RETAIN THE SERVICES OF AN INDEPENDENT SOILS CONSULTANT AND TESTING LABORATORY TO PERFORM SOIL ANALYSIS, FIELD COMPACTION, AND DENSITY TESTS AND CHECK COMPLIANCE WITH THESE SPECIFICATIONS. THE CONTRACTOR SHALL BE REQUIRED TO REMOVE SURFACE MATERIALS AT LOCATIONS DESIGNATED BY THE TESTING ENGINEER AND TO PROVIDE ASSISTANCE AS NECESSARY FOR TESTING. THE INDEPENDENT TESTING LABORATORY WILL SAMPLE AND PERFORM ALL REQUIRED TESTS SUCH AS MOISTURE CONTENT, GRADATION AND MOISTURE DENSITY RELATIONSHIPS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY SCHEDULING INSPECTION AND TESTING OF ALL FACILITIES CONSTRUCTED UNDER THIS CONTRACT. ALL TESTING AND INSPECTION WILL BE PAID FOR BY THE OWNER. ALL RE-TESTING AND/OR REINSPECTION SHALL BE PAID FOR BY THE CONTRACTOR. S D W W SANITARY SEWER FORCE MAIN STORM DRAIN LINE GRAVITY SANITARY SEWER LINE WATER LINE DRAIN LINE FIRE SERVICE LINE GAS LINE COMMUNICATION LINE ELECTRICAL LINE FORCED AIR LINE IRRIGATION LINE SIDEWALK EDGE OF PAVEMENT R/W, PL BOX CULVERT DRAINAGE SWALE OR GUTTER FLOWLINE CMU WALL TEMPORARY PIPING BLOW-OFF CATCH BASIN CLEANOUT ELEVATION BENCH MARK FOUND MONUMENT GUY WIRE HORIZONTAL AND VERTICAL CONTROL POINT MAN HOLE PG&E TRANSFORMER PG&E SUBSURFACE ENCLOSURE POST, BOLLARD, OR PARKING METER GATE VALVE PLUG VALVE LINE STOP REDUCER CHECK VALVE BACK FLOW PREVENTER PULL BOX SIGN POST LOCATION SPOT ELEVATION STREET LIGHT SURVEY CONTROL POINT TRAFFIC SIGNAL UTILITY POLE WATER METER WATER VALVE ROOF DRAIN SLOPE/FLOW DIRECTION GRADE WW TRAFFIC CONTROL: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL NECESSARY FOR THE PROJECT AND AS DESCRIBED IN THE PROJECT SPECIFICATIONS. 2. CONTRACTOR IS RESPONSIBLE FOR DESIGNING AND IMPLEMENTING TRAFFIC CONTROL THAT MEETS THE MINIMUM REQUIREMENTS NOTED ON THE PLANS AND SPECIFICATIONS. TRAFFIC CONTROL PLANS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF CALIFORNIA AND CONSISTENT WITH ACCEPTED STANDARDS INCLUDING THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. UNLESS NOTED OTHERWISE, TWO-WAY TRAFFIC SHALL BE MAINTAINED AT ALL TIMES ON BOTH DATE AND P STREETS. 3. THROUGHOUT ALL PHASES OF CONSTRUCTION, INCLUDING SUSPENSION OF WORK, AND UNTIL FINAL ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL KEEP PREMISES IT OCCUPIES IN A CLEAN AND ORDERLY CONDITION, DISPOSING OF REFUSE IN A MANNER SATISFACTORY TO THE ENGINEER. CONSTRUCTION NOTES: 1. THE CONTRACTOR SHALL LAYOUT IMPROVEMENTS FROM THE DIMENSIONS SHOWN ON THE PLANS. ANY CLARIFICATION ON CONFLICTS, DISCREPANCIES OR AMBIGUITIES SHOULD BE DIRECTED TO THE ENGINEER PRIOR TO THE CONSTRUCTION OF THE IMPROVEMENTS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MATCHING EXISTING SURROUNDING LANDSCAPE AND OTHER IMPROVEMENTS WITH A TRANSITION IN PAVING, CURBS, GUTTERS, SIDEWALKS, GRADES, ETC., AND TO AVOID ANY ABRUPT OR APPARENT CHANGES IN CROSS SLOPES, LOW SPOTS, OR HAZARDOUS CONDITIONS. 3. WHERE PAVEMENT IS TO BE EXTENDED OR REMOVED, EXISTING PAVEMENT SHALL BE SAW-CUT OR GROUND TO A NEAT LINE PRIOR TO PLACING NEW ASPHALT CONCRETE. 4. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN TEMPORARY SIGNS FOR ALL REGULATORY TRAFFIC SIGNS REMOVED DURING THE CONSTRUCTION. 5. IT IS PROHIBITED TO DISCHARGE ANYTHING EXCEPT GROUND WATER INTO THE AGRICULTURAL DITCH. ALL GROUND WATER DISCHARGES MUST BE IN ACCORDANCE WITH THE PROJECT RWQCB DEWATERING PERMIT. TO BE ABANDONED TO BE DEMOLISHED TO BE MODIFIED LANDSCAPE READY STRIP FG 75.90 CONTROLLED DENSITY FILL

PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 GENERAL ABBREVIATIONS 04 G-004 NTSBDW PX BDW GENERAL ABBREVIATIONS AB ANCHOR BOLT OR AGGREGATE BASE ABAN ABANDONED AC ASPHALT CONCRETE ACP ASBESTOS CEMENT PIPE AD AGRICULTURAL DRAIN APPROX APPROXIMATE ARV AIR RELEASE AND VACUUM RELIEF COMBINATION VALVE BC BOX CULVERT BF BLIND FLANGE BFP BACK FLOW PREVENTER BLDG BUILDING BOC BACK OF CURB BOT BOTTOM BM BENCH MARK, OR BEAM BMP BEST MANAGEMENT PRACTICES BV BALL VALVE CALTRANS CALIFORNIA DEPARTMENT OF TRANSPORTATION CAV COMBINATION AIR VALVE CB CATCH BASIN, COMMUNICATION BOX CBC CALIFORNIA BUILDING CODE C/C CENTER TO CENTER CDF CONTROLLED DENSITY FILL CJ CONSTRUCTION JOINT CI CAST IRON CIP CAST IRON PIPE/IN PLACE CL, CENTER LINE CLR CLEAR CLSM CONTROLLED LOW STRENGTH MATERIAL CML&C CEMENT MORTAR LINED & COATED CMP CORRUGATED METAL PIPE CMU CONCRETE MASONRY UNIT CO CLEAN OUT COM COMMUNICATIONS CONC CONCRETE CONN CONNECT CONT CONTINUOUS COTG CLEANOUT TO GRADE CP CONTROL POINT AND COORDINATE POINT CPLG COUPLING CTR CENTER CTRL CONTROL C&G CURB AND GUTTER CG&S CURB, GUTTER & SIDEWALK CV CHECK VALVE CY CUBIC YARD DB DUCT BANK DBL DOUBLE DEPT DEPARTMENT DET DETAIL DI DRAIN/DROP INLET DIA DIAMETER/DIAGONAL DIM DIMENSION DIP DUCTILE IRON PIPE DIA DIAGONAL DISCH DISCHARGE DN DOWN DS DRAINAGE SWALE D/W DRIVEWAY DWG DRAWING E OR (E) EAST/EASTING OR EXISTING EA EACH, EXHAUST AIR EB ELECTRICAL BOX ECC ECCENTRIC EFF EFFLUENT EG EXISTING GRADE EL, ELEV ELEVATION ELEC/ELC ELECTRICAL ELL, ELB ELBOW EP EDGE OF PAVEMENT FA FORCE AIR/FOUL AIR FC FLEX COUPLING FCA FLANGED COUPLING ADAPTER FF FINISH FLOOR FG FINISH GRADE FL FLOW LINE FLG FLANGE FLR FLOOR FM FORCE MAIN FNPT FEMALE NATIONAL PIPE THREAD FOC, FC FACE OR CURB FT FOOT OR FEET FTG FOOTING G GAS GA GAGE GAL GALLONS GALV GALVANIZED GB GRADE BREAK GEN GENERAL GI GROUND LINE GPD GALLONS PER DAY GPM GALLONS PER MINUTE GR GRADE/GRATE GSP GALVANIZED STEEL PIPE GV GATE VALVE HB HOSE BIBB HGL HYDRAULIC GRADE LINE HORIZ HORIZONTAL HP HORSEPOWER, HIGH PRESSURE OR HIGH POINT HWL HIGH WATER LEVEL ID INSIDE DIAMETER IE INVERT ELEVATION IF INSIDE FACE IN INCHES INV INVERT IP IRON PIPE IRR IRRIGATION JP JOINT POINT JS JUNCTION STRUCTURE JT JOINT KV KILOVOLT L LENGTH OF CURB OR LENGTH LBS POUNDS LCP LOCAL CONTROL PANEL LF LINEAL FEET LG LENGTH OR LONG LIN LINEAR LP LOW PRESSURE, LOW POINT, OR LONG RADIUS LT LEFT LWL LOW WATER LEVEL MAX MAXIMUM MFR MANUFACTURER MH MAN HOLE MIN MINIMUM MJ MECHANICAL JOINT MNPT MALE NATIONAL PIPE THREAD (N) NEW N/A NOT APPLICABLE NC NORMALLY CLOSED NIC NOT IN CONTRACT NGS NATIONAL GEODETIC SURVEY NO NORMALLY OPEN, NUMBER NP NON-POTABLE NTS NOT TO SCALE OA OUTSIDE AIR OC ON CENTER OD OUTSIDE DIAMETER OF OVERFLOW OR OUTSIDE FACE OG ORIGINAL GROUND OPER OPERATED OR OPERATOR OPNG OPENING OSA OUTSIDE AIR PB PULL BOX, POWER BOX PC POINT OF CURVE (BEGIN CURVE), PIECE, OR PRIMARY CONTROL PCC PORTLAND CEMENT CONCRETE, POINT OF COMPOUND CURVE PGRM PROGRAM PIV POST INDICATOR VALVE PID PROJECT IDENTIFIER PL/P/L PLATE OR PROPERTY LINE PLC PROGRAMMABLE LOGIC CONTROLLER POC POINT OF CONNECTION PP POWER POLE PRESS PRESSURE PRV PRESSURE REGULATING VALVE PSF POUND PER SQUARE FOOT PSI POUND PER SQUARE INCH PS PUMP STATION PW PLANT WATER, POTABLE WATER PV PLUG VALVE PVC POLYVINYL CHLORINE PVCP POLYVINYL CHLORIDE PIPE PVMT, PAV PAVEMENT R OR (R) RADIUS, RETURN OR RIDGE RA RETURN AIR RC RELATIVE COMPACTION RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN REBAR REINFORCEMENT BARS RED REDUCER REF REFERENCE REINF REINFORCING, REINFORCEMENT REQ'D REQUIRED RET RETURN REV REVISION RM RIM/LID R&R REMOVE & REPLACE R&W REMOVE & WASTE R&S REMOVE & SALVAGE RS RAW SEWAGE RT RIGHT RW RECYCLED WATER R/W / ROW RIGHT-OF-WAT S SOUTH OR SLOPE SA SAMPLE, SUPPLY AIR SAN SANITARY SEWER SB SIGNAL PULL BOX SCH SCHEDULE SD STORM DRAIN SDMH STORM DRAIN MAINTENANCE HOLE SDR STANDARD DIMENSION RATIO SECT SECTION SF SQUARE FOOT SHT SHEET SIM SIMILAR SOV SHUT OFF VALVE SP STATIC PRESSURE SPEC SPECIFICATION OR SPECIAL SQ SQUARE SQFT SQUARE FEET SQIN SQUARE INCH SQYD SQUARE YARD SS STAINLESS STEEL OR SANITARY SEWER SSMH SANITARY SEWER MAINTENANCE HOLE SST STAINLESS STEEL STA STATION STD STANDARD STIFF STIFFENER STL STEEL STRUCT STRUCTURE OR STRUCTURAL SUP SUPPORT SYM SYMMETRICAL SW SEAL WATER SWITCH, SERVICE WATER, OR SIDEWALK SWBD SWITCHBOARD T TANGENT LENGTH OR TELEPHONE T&B TOP & BOTTOM TBM TEMPORARY BENCH MARK TC TOP OF CURB/CONCRETE TEL TELEPHONE TEMP TEMPORARY TFR TEMPORARY FIBER ROLL TG TOP OF GUTTER OR TOP OF GRATE THK THICK TOC TOP OF CONCRETE TOF TOP OF FILL, TOP OF FLOOR TOP TOP OR TOP OF PIPE TSO TOP OF STEEL TP TELEPHONE POLE TPB TELEPHONE PULL BOX TS THICKENED SLUDGE, TOP OF SLOPE TOW/TW TOP OF WALL/WALK TYP TYPICAL UD UNDER DRAIN UG UNDERGROUND UON UNLESS OTHERWISE NOTED UNKN UNKNOWN V VENT VAR VARIOUS, VARIES VLT VAULT VERT VERTICAL VPI VERTICAL POINT OF INFLECTION VTR VENT THROUGH ROOF W WEST, WATER, WIDTH, WIDE W/ WITH (PREFIX) W/O WITHOUT (PREFIX) WL WATER LEVEL WS WATER SURFACE, WATERSTOP WSP WELDED STEEL PIPE WT WEIGHT SFRM TRANSFORMER YD YARD OR YARD DRAIN N,S,E,W CARDINAL DIRECTIONS CHARACTERS ℄ CENTERLINE Ø DIAMETER ∠ ANGLE @ AT Δ DEFLECTION ANGLE

SURVEY CONTROL STATEMENT BASIS OF SURVEY CONTROL: COORDINATES , BEARINGS, AND DISTANCES ARE BASED UPON THE NORTH AMERICAN DATUM OF 1983 (NAD 83 2011), 2010.00 EPOCH DATE ADJUSTMENT, CONVERTED TO THE CALIFORNIA COORDINATE SYSTEM OF 1983, ZONE 2 (CCS83-Z2). ALL COORDINATES AND DISTANCES ARE GRID. GROUND DISTANCES MUST BE MULTIPLIED BY A COMBINED SCALE FACTOR (CSF) OF 0.999920925 TO OBTAIN GRID DISTANCES. UNITS SHOWN ARE BASED ON THE U.S. SURVEY FOOT. A CONVERGENCE ANGLE OF +0°12'36.9" AND THE CSF WERE DETERMINED AT CONTROL POINT 501. ELEVATIONS ARE REFERENCED TO THE CITY OF LIVE OAK'S BM NUMBER 9 (ELEVATION 74.92'), BASED UPON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88). CONTROL TABLE POINT # 101 102 501 502 503 504 505 NORTHING 2225895.49 2210502.22 2225201.05 2225177.25 2225219.36 2224693.82 2225292.71 EASTING 6657486.43 6645037.78 6656078.12 6656078.21 6656197.22 6656209.89 6656136.34 ELEVATION 77.55 70.64 75.25 74.30 74.92 74.13 75.49 DESCRIPTION NGS PID KS0909 - A SURVEY DISK SET IN THE TOP OF A CONCRETE MONUMENT STAMPED - P 845 1949 NGS PID DL9183 - A SURVEY DISK SET IN A RETAINING WALL STAMPED - MORRISON 2007 SET MAG NAIL - KSN CONTROL FOUND BRASS DISK 1.5-INCH WITH PUNCH - NO TAG FOUND BRASS DISK 2.5-INCH CITY OF LIVE OAK BM 9 FOUND BRASS DISK 1.5-INCH WITH PUNCH - NO TAG FOUND IPIN 5/8-INCH - NO TAG NOTE: 1. 100 SERIES POINTS ARE PRIMARY NGS CONTROLS. 2. 500 SERIES POINTS ARE LOCAL PROJECT CONTROL. DATE ST "P" ST FIR ST PLUM ST 501 502 503 504 505 soft Corporation © 2020 Maxar ©CNES (2020) Distribution Airbus DS 99 APRICOT ST LARKIN RD DATE ST "P" ST "P" ST FIR ST PLUM ST 101 102 501 502 503 504 505 99 LARKIN ROAD TOWNSHIP ROAD CLARK ROAD PENNINGTON ROAD PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 SCALE: 1" = 200' SCALE: 1" = 1000' SURVEY CONTROL PLAN V-00105 AS SHOWN CGS KFN

S 10001 S 10002 S 10005 W W S 10011 S 10012 S 10058 12 INCH CMP INV EL 73.61 12 INCH RCP INV EL 74.08 12 INCH RCP INV EL 73.88 TOP OF HEADWALL EL 74.61 30 INCH RCP INV EL 72.12 12 INCH RCP INV EL 72.05 EM W W W 10416 10417 B B1 B B3 S 10500 B B2 2 INCH CONDUIT TO ANTENNA 10418 FINISHED FLOOR EL 76.18 75 7473 73 74 75 75 74 73 73 74 75 76 76 75 75 75 74 74 76 76 76 75 501 502 503 505 INSIDE TOP 20IN RCP EL 73.68 D 10004 D 10006 10007 D 10008 D 10013 D 10003 GATE POST GATE POST FUEL TANK 3 CONDUITS TO BUILDING S 10375 12 INCH WHITE ROAD STRIPING 6 INCH WHITE ROAD STRIPING 12 INCH DOUBLE YELLOW ROAD STRIPING6 INCH WHITE DASHED ROAD STRIPING 7FT CHAIN LINK FENCE 7FT CHAIN LINK FENCE WOOD FENCE WOOD FENCE DATE STREET SHEET NOTE: 1. LOCATIONS OF BURIED UTILITY MARKINGS WHERE SURVEYED ARE SHOWN ON SHEET C-003 YARD PIPING PLAN. P STREET GENERATOR 75 PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 NORTH ORIENTATION N DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 EXISTING CONDITIONS TOPOGRAPHIC MAPPING V-20106 1" = 10' CGS KFN 1 USA POTHOLES AND UTILITY INVERTS 5/12/2021 KFN 1" = 10'

UTILITY INVERT TABLE POINT # STRUCTURE # NORTHING EASTING TYPE ESTIMATED DIAMETER (INCHES) DIRECTION RIM ELEVATION (FEET) MEASURE DOWN (MD) (FEET) INVERT ELEVATION (FEET) NOTES 10001 FLOW METER VAULT 2225218.68 6656098.09 SS MH 12 N-S 76.31 5.90 NA TOP OF PIPE ELEVATION 70.41, NO ACCESS TO INVERT 12 N-S 76.31 5.90 NA TOP OF PIPE ELEVATION 70.41, NO ACCESS TO INVERT NA NA 76.31 6.90 69.41 BOTTOM OF VAULT 10002 SSMH AA 2225198.58 6656064.31 SS MH 14 NE 75.13 9.95 65.18 14 W 75.13 10.00 65.13 10003 2225148.29 6656077.67 SD MH 30 N 75.48 4.00 71.48 54 NE 75.48 8.90 66.58 FILLED WITH MUD 54 S 75.48 8.90 66.58 FILLED WITH MUD 12 NW 75.48 4.50 70.98 10004 2225168.7 6656098.41 SD MH 54 E 75.10 8.70 66.40 FILLED WITH MUD 54 SW 75.10 8.45 66.65 10005 SSMH AAA 2225188.75 6656126.33 SS MH 8 N 74.99 9.70 65.29 8 W 74.99 9.70 65.29 10006 2225184.35 6656130.78 SD MH 14 N 75.08 8.98 66.10 DIRT IN PIPE 10 W 75.08 8.93 66.15 10007 2225197.13 6656125.09 SD CI 12 NW 74.33 2.31 72.02 10008 2225172.88 6656189.13 SD MH 48 N 75.08 8.23 66.85 36 E 75.08 6.90 68.18 50 W 75.08 8.67 66.41 10011 SSMH A 2225248.25 6656172.91 SS MH 12 N 75.41 9.30 66.11 12 S 75.41 9.30 66.11 14 W 75.41 9.40 66.01 10012 SSMH B 2225272.73 6656172.86 SS MH 6 N 75.52 8.50 67.02 10 E 75.52 9.88 65.64 12 S 75.52 8.90 66.62 10013 2225285.4 6656185.23 SD MH 48 N 75.39 7.25 68.14 24 E 75.39 4.60 70.79 48 S 75.39 7.10 68.29 10058 SSMH AA0.2 2225270.44 6656128.48 SS MH 14 S 75.69 10.65 65.04 14 W 75.69 10.50 65.19 10375 JS 2225248.76 6656132.65 SS MH 12 N 76.10 11.20 64.90 16 E 76.10 10.10 66.00 16 W 76.10 11.60 64.50 ? W 76.10 ? GATE CLOSED, PIPE NOT ACCESSIBLE 10500 SSMH AA0.1 2225267.46 6656100.47 SS MH 14 E 76.12 11.00 65.12 14 SW 76.12 10.85 65.27 WET WELL POINT # NORTHING EASTING TYPE ESTIMATED DIAMETER DIRECTION RIM ELEVATION MEASURE DOWN (MD) INVERT ELEVATION NOTES 10416 2225250.51 6656108.2 VLT 1 ? S 76.97 6.60 NA TOP OF PIPE ELEVATION 70.37 NA 76.97 19.50 57.47 BOTTOM OF VAULT NA 76.97 9.60 67.37 TOP OF WALL 10417 2225250.78 6656114.96 VLT 2 ? S 76.96 6.60 NA TOP OF PIPE ELEVATION 70.36 N 76.96 6.50 NA TOP OF VERTICAL OF PIPE ELEVATION 70.46 NA 76.96 19.40 57.56 BOTTOM OF VAULT NA 76.96 9.70 NA TOP OF WALL 67.26 10418 2225250.68 6656119.39 VLT 3 NA NA 76.97 9.95 NA TOP OF WALL 67.02 NA 76.97 12.00 64.97 BOTTOM OF TROUGH NA 76.97 9.60 NA TOP OF WALL 67.37 NA 76.97 19.40 57.57 BOTTOM OF VAULT 16 E 76.97 11.90 65.07 16 E 76.97 11.90 65.07 PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 NORTH ORIENTATION N DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 UTILITY INVERT TABLE V-20207 NTS CGS KFN 1 USA POTHOLES AND UTILITY INVERTS 5/12/2021 KFN

12" @ 95% COMPACTION VARIES @ 90% COMPACTION "D" (TYP) SEE NOTE 1 OD + (2 x "D") SEE NOTE 1 SEE NOTE 4 12" MIN (EXIST ROAD ONLY) AC PAVEMENT UNPAVED AREAS 95% COMPACTION COMPACT NATIVE FILL IN 6" MAX LIFTS TO A MIN RELATIVE COMPACTION OF 95% UNDER ROADWAY, AND 90% IN UNPAVED AREAS COMPACT NATIVE FILL IN 6" MAX LIFTS TO A MIN RELATIVE COMPACTION OF 90% CRUSHED ROCK WITH FILTER FABRIC WRAP6" @ 90% COMPACTION FINISHED GRADE (TYP) ROADWAY TRACER WIRE SEE NOTE 5 O.D. 12" @ MIN. 90% COMPACTION NOTES: 1. FOR PIPE O.D. OF 0" TO 24", "D" = 6" MIN. FOR PIPE O.D. OF 24" AND GREATER, "D" = 12" MIN. 2. THIS DETAIL IS APPLICABLE TO STABLE SOIL CONDITIONS ONLY. 3. RELATIVE COMPACTION OF MATERIALS SHALL BE TESTED IN ACCORDANCE WITH THE STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION TESTING MANUALS, TEST METHOD NO. CALIFORNIA 216 OR 231. 4. FOR REPAIR IN ROADWAYS MATCH EXISTING PAVEMENT THICKNESS. 5. INSTALL TRACER WIRE - TRACER WIRE SHALL BE MINIMUM #10 AWG SOLID COPPER WIRE WITH 45 MILS OF HIGH MOLECULAR WEIGHT POLYETHYLENE(HMWPE) INSULATION, UL LISTED, RATED FOR DIRECT BURIAL, COLOR PER USA RECOMMENDED COLORS. NOT REQ'D FOR FORCE MAIN PIPE FROM WET WELL TO FLOWMETER VAULT, GRAVITY SEWER, OR STORM DRAIN PIPES. 1 GC-001 NTS TYPICAL TRENCH SECTION 42" 36" 6" PAINT BOLLARD WITH YELLOW EPOXY PAINT. ADD 3 RINGS OF REFLECTIVE TAPE 6" SCH 40 GALV STEEL PIPE FILLED WITH CONCRETE ROUND OFF TOP WITH GROUT PLUG PROVIDE 1/4" PER FOOT SLOPE AT BOLLARD BASE TO DRAIN MIN 18"Ø, 3000 PSI CLASS 3 CONCRETE FOOTING 2 GC-001 NTS PERMANENT BOLLARD NEW CONCRETE FLAT TOP 60" JOINT SEALANT TYP PRE CAST REINFORCED BARREL SECTION (REBAR NOT SHOWN) 2" MIN (ANTI-FLOTATION FOR [PRECAST BASES) FLOW LINE FLOW LINE 4 GC-001 NTS NEW A-AA JUNCTION STRUCTURE NOTES: 1. CLASS A ASTM C478 CONCRETE TO BE USED FOR BARRELS & USED IF A PRECAST BASE. 2. JOINTS FOR THE BARREL SECTION WILL BE TONGUE AND GROOVE OR LAP JOINT. ALL LIFTING HOLES MUST BE SEALED WITH NON-SHRINK GROUT. 3. PRECAST BASES, IF USED, SHALL BE PLACED ON 10" MIN OF 3/4" CRUSHED ROCK PLACED OVER UNDISTURBED MATERIAL. 4. CONNECTION OF THE PIPE TO THE MANHOLE MUST USE AN INTEGRALLY CAST BOOT OR BELL. KOR-N-SEAL BOOT OR EQUAL PER ASTM C923 (TYP) N O T E S : FINISHED GRADE CONCRETE COLLAR EXTENSIONS TO BE ONE CONTINUOUS PIECE. 9" 7-1/2" 12" 12" (N) 12" SSFM EXTENSIONS 30" MIN. DEPTH VALVE BOX SHOWN IS "CHRISTY (NO. G8)" 14-1/2"± 5/8" 19-1/4" 13-1/4" CAST IRON LID 6" TYP. 3 GC-001 NTS TRACER WIRE ACCESS BOX TRACE WIRE SPLICE DETAIL 5 GC-001 NTS ROLLER GATE DETAIL 6 GC-001 NTS ROLLING GATE CARRIER TRACK DETAIL TO (N) WET WELL COVER SPLICE WITH ELECTRICAL TAPE SOLDERED CONNECTION SEE DETAIL 12X10 REDUCER SPLICE (N) AND (E) TRACER WIRE (E) TRACER WIRE (E) 10" SSFM IN STREET AREA AC TO MATCH (E) PLACED DURING RESTORATION 2-#4 HOOKS, TYP SEE SLIDE GATED MOUNTING AND SEATING DETAIL 60" Ø FLAT TOP MH 1. VALVE BOX AND LID SHALL BE CHRISTY NO. G8 OR EQUAL. VALVE BOX AND LID 2. ALL LIDS SHALL HAVE MACHINED SEATING SURFACES. 3. EXTENSIONS SHALL BE AS MANUFACTURED FOR THE VALVE BOX SUPPLIED. 4. TRACER WIRES MAY ALL BE MADE ACCESSIBLE IN A SINGLE VALVE BOX. CONTRACTOR SHALL CLEARLY TAG EACH TRACER WIRE TO IDENTIFY ASSOCIATED PIPE (DEDICATED OR MANIFOLDING) AND SIDE (LIFT STATION OR TREATMENT PLANT). SPUR GEAR OPERATING NUT 16" MAX TRAVEL VARIES BUILT IN STEEL ROLLERS (MIN OF 2) TO RIDE ON CARRIER TRACK. SEE DETAIL 6, THIS SHEET 6'-0" 1'-0" 6" NOTES: 1. SEE SPECIFICATION 02820 FOR GATE FABRICATION DETAILS 1'-6" 1/4" GALV STEEL PLATE (MIN) WELDED TO TRACK 1/4" GALV STEEL TRACK. SIZE AND LENGTH AS REQUIRED. MOUNT PER MFR RECOMMENDATIONS OR AS SHOWN (MORE STRINGENT DESIGN CONTROLS) CONCRETE BOLT 2-#4 @12" AB AC 12" 8" MIN 3'-0" (TYP) NOTE: 1. LEAVE 30" GAP WHEN CROSSING DRAINAGE SWALES. PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 CIVIL DETAILS 1 08 GC-001 AS SHOWNBDW PX BDW 4 GC-002 5 M-001

4" AC 16" CLASS-2 AB AT 95% MIN RC SCARIFY AND RECOMPACT TOP 8" TO 95% MIN RC ASPHALT PAVING 4 GC-002 NTS PAVING DETAILS C.I. FRAME & COVER W/ SST ALLEN HEAD SET SCREW PVC GRAVITY PIPE OR DI PRESSURE PIPE CONC ENCASEMENT 2'-6" x 2'-6" x 2'-6" (LxWxD) AC OR CONC PAVEMENT GRAVITY SYSTEMS PRESSURE SYSTEMS PVC PLUG CLEANOUT GRAVITY SYSTEM. BLIND FLANGE W/ BOLTS & NUTS FOR PRESSURE SYSTEMS. 5 GC-002 NTS CLEANOUT 1 GC-002 NTS CITY LIVE OAK - STD DET 201 2 GC-002 NTS CITY LIVE OAK - STD DET 202 3 GC-002 NTS CITY LIVE OAK - STD DET 204A PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 CIVIL DETAILS 2 09 GC-002 AS SHOWNBDW PX BDW

1 GC-003 NTS CITY LIVE OAK - STD DET 204B 2 GC-003 NTS CITY LIVE OAK - STD DET 206A 3 GC-003 NTS CITY LIVE OAK - STD DET 206C PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 CIVIL DETAILS 3 10 GC-003 AS SHOWNBDW PX BDW

City of Live Oak Public Works Improvement Standards City of Live Oak Public Works Improvement Standards City of Live Oak Public Works Improvement Standards 1 GC-004 NTS CITY LIVE OAK - STD DET 404 2 GC-004 NTS CITY LIVE OAK - STD DET 405 3 GC-004 NTS CITY LIVE OAK - STD DET 411 PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 CIVIL DETAILS 4 11 GC-004 AS SHOWNBDW PX BDW

City of Live Oak Public Works Improvement Standards City of Live Oak Public Works Improvement Standards 2 GC-005 NTS CITY LIVE OAK - STD DET 504 3 GC-005 NTS CITY LIVE OAK - STD DET 5071 GC-005 NTS CITY LIVE OAK - STD DET 414PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 CIVIL DETAILS 5 12 GC-005 AS SHOWNBDW PX BDW

1 GC-006 NTS CALTRANS - STD DET D84 PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 CIVIL DETAILS 6 13 GC-006 AS SHOWNBDW PX BDW

PLAN VIEW NOTES: 1. SEDIMENT TRAPPED UPSTREAM OF SEDIMENT CONTROL BMP SHALL BE REMOVED WEEKLY AND PRIOR TO ANTICIPATED RAINFALL EVENTS. 2. PLACE BMP'S TIGHTLY TOGETHER AT JOINTS TO PREVENT OR MINIMIZE SEEPAGE AT JOINTS. BACK OF CURB FACE OF CURB GRAVEL BAG(S) OR OTHER ACCEPTED SEDIMENT CONTROL BMP. PLACE BAGS TIGHT AGAINST FACE OF CURB. SEE NOTE 2 LIP OF GUTTER DRAINAGE INLET WITH FILTER FABRIC FLOW GRAVEL BAG INLET SEDIMENT CONTROL MIN BAG WIDTH (BACK OF GRATE) 2" MIN MAX BAG WIDTH 2" MIN AT BACK EXISTING OPEN BACK HOOD CONTACT AT FRONT AND SIDES DETAIL A EXISTING DROP INLET GRATE FILTER BAG FRAME (OPTIONAL) EXISTING DROP INLET FRAME DETAIL A DETAIL ACURB EXISTING DROP INLET GRATE CONTACT ALL SIDES OUTLET PIPE NOTES: 1. THE FILTER BAG SHALL BE MANUFACTURED FROM UV RESISTANT POLYPROPYLENE NYLON, POLYESTER, OR ETHYLENE FABRIC WITH A MINIMUM TENSILE STRENGTH OF 50 LBS PER LINEAR FOOT. AN EQUIVALENT OPENING SIZE NOT GREATER THAN A 20 SIEVE AND WITH A MINIMUM FLOW RATE OF 40 GALLONS/MINUTE/SF. 2. THE FILTER BAG MAY BE SUSPENDED FROM OR HELD IN PLACE BY THE EXISTING INLET GRATE (OR OTHER APPROVED METHOD) PROVIDING NO MODIFICATION OR DAMAGE SHALL BE DONE TO THE INLET GRATE OR FRAME. THE INLET GRATE SHALL NOT BE CAUSED TO REST MORE THAN 0.5" ABOVE THE INLET FRAME (SEE DETAIL A). 3. THE FILTER BAG MAY EXTEND TO THE BOTTOM OF THE INLET BOX PROVIDED THE OUTLET PIPE IS UNOBSTRUCTED. 4. FLOWS SHALL NOT BE ALLOWED TO BYPASS PROTECTION MEASURES. 5. INLET FILTER BAGS SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL DURING THE WET SEASON AND MONTHLY DURING THE DRY SEASON. SEDIMENT AND DEBRIS SHALL BE REMOVED BEFORE ACCUMULATIONS HAVE REACHED ONE THIRD THE DEPTH OF THE BAG. BAGS SHALL BE REPAIRED OR REPLACED AS SOON AS DAMAGE OCCURS.INLET FILTER BAG GRATE 1. FILTER FABRIC SHALL BE A GEOTEXTILE WOVEN MATERIAL. 2. FABRIC MATERIAL STRENGTH AND USE OF ADDITIONAL LAYERS SHALL SUIT THE LEVEL OF RUNOFF AND ENTRAINED SEDIMENT NEEDED TO PROTECT THE INLET. 3. FABRIC SHALL EXTEND A MINIMUM OF 6-INCHES BEYOND EDGE OF GRATE. 4. AT HOODED CURB INLETS, FABRIC SHALL EXTEND ABOVE THE TOP OF CURB, USE GRAVEL BAGS AS NECESSARY TO HOLD THE FABRIC AND TO BERM AGAINST BYPASS. 5. FILTERS SHALL BE INSPECTED WEEKLY AND REPLACED WITH CLEAN FABRIC WHENEVER SEDIMENT AND DEBRIS IS VISIBLE. FILTER FABRIC FILTER FABRIC INLET FILTER FABRIC 1. ALL INLET BMP PROTECTION MEASURES SHALL INCLUDE AT A MINIMUM FILTER FABRIC UNDER GRATES AND LIDS. GRAVEL BAG BERMS AND INLET PERIMETERS SHALL BE ADDED WHEN FABRIC HAS POTENTIAL FOR BEING OVERLOADED. FILTER BAGS SHALL BE ADDED WHEN AN INLET IS AT RISK TO FILTERING OF HEAVY SEDIMENT LADEN RUNOFF, I.E. WET WINTER CONSTRUCTION CONDITIONS. 1 TEMPORARY STORM DRAIN INLET FILTERS NTS FLOW A A 4 FEET MAX 4 FEET MAX 4 INCH MAX 2 INCH MIN 12 INCH MIN SLOPE VARIES FIBER ROLL 8 INCH MIN INSTALL A FIBER ROLL NEAR SLOPE WHERE IT TRANSITIONS INTO A STEEPER SLOPE 3/4 IN X 3/4 IN WOOD STAKES MAX 4 FT SPACING NOTES: 1. INSTALL FIBER ROLLS IN A ROW ALONG A LEVEL CONTOUR. 2. AT ENDS OF A ROW TURN THE LAST TWO FEET UP SLOPE SLIGHTLY. 3. FIBER ROLLS SHALL BE BUTTED TIGHTLY AT THE JOINTS. 4. DO NOT OVERLAP JOINTS. SECTION A-A TYPICAL FIBER ROLL INSTALLATION CONSTRUCTION SITE OFF-SITE 15' MIN A ADIRECTION OF TRAVEL CONSTRUCTION SITE RIGHT OF WAY 50 FEET MINIMUM OR AS APPROVED BY THE ADMINISTRATOR 1-3 INCH WASHED, WELL GRADED GRAVEL OR CRUSHED ROCK EXISTING GROUND GEOTEXTILE MATERIAL 6 INCHES MIN SECTION A-A PLAN VIEW NOTES: 1. STABILIZED CONSTRUCTION SITE ACCESS SHALL BE CONSTRUCTED OF 1-3 INCH WASHED, WELL GRADED GRAVEL OR CRUSHED ROCK. MATERIAL SHALL BE PLACED TO A MINIMUM THICKNESS OF 6 INCHES. 2. LENGTH OF ENTRANCE SHALL BE OF SUITABLE LENGTH TO PREVENT TRACK OUT. WIDTH SHALL BE A MINIMUM OF 15 FEET OR GREATER IF NECESSARY TO COVER ALL VEHICULAR INGRESS AND EGRESS. PROVIDE AMPLE TURNING RADII. 3. THE ENTRANCE SHALL BE KEPT IN GOOD CONDITION BY OCCASIONAL TOP DRESSING WITH MATERIAL AS SPECIFIED IN NOTE 1. 4. ACCESSES SHALL BE INSPECTED WEEKLY DURING PERIODS OF HEAVY USAGE, MONTHLY DURING NORMAL USAGE, AND AFTER EACH RAINFALL, WITH MAINTENANCE PROVIDED AS NECESSARY. PERIODIC TOP DRESSING SHALL BE DONE AS NEEDED. 3 TEMPORARY STABILIZED CONSTRUCTION SITE ACCESS NTS 2 TEMPORARY FIBER ROLLS NTS PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 CIVIL DETAILS 7 EROSION AND SEDIMENT CONTROL GC-00714 NTS BDW PX BDW

S S S D S S S EM W W W S S S S CONTRACTOR TO CLEAN & CCTV LINE. CITY TO PROVIDE EXTENT OF SS TO R&R W/ (N) 12" SDR 35. R&W OR ABANDON APPROX 15' ROUTING INTO (E) A-AA-AAA JS (E) SSMH A R&W (E) FLOW METER VAULT IF (N) BOX CULVERT OPTIONAL BID ITEM A INSTALLED, R&W (E) HEADWALL R&W (E) SSMH AA0.1 R&R (E) SSMH AA R&W (E) SSMH AA0.2 REMOVE AND TEMPORARILY REPLACE (E) STREET SIGN AS NECESSARY DURING CONSTRUCTION, REMOUNT (E) SIGN WHEN CMU WALL IS COMPLETE R&W (E) FENCE AROUND (E) FACILITIES R&W (E) 15" SS LINE SEE NOTE 11 R&W OR ABANDON (E) 15" SS LINE BETWEEN (E) SSMH AA0.1 AND (E) SSMH AA0.2 ONCE FLOW DIVERSION IS NO LONGER REQUIRED. SEE NOTE 9 R&R (E) ROOF, (E) BLDG TO BE RE-USED. SEE NOTES 2 & 3 R&W OR ABANDON (E) 15" SS LINE BETWEEN (E) SSMH AA0.2 AND (E) A-AA-AAA JS ONCE FLOW DIVERSION IS NO LONGER REQUIRED. SEE NOTE 9 (E) WET WELL, R&W ALL ABOVE GROUND FACILITIES. REMOVE (E) CMU WALL TO 16" BELOW (E) GRADE. (N) SS PIPE TO BE ROUTED THROUGH (E) WET WELL AFTER (N) LIFT STATION IS ACCEPTED AS OPERATIONAL. AFTER (N) SS PIPE IS INSTALLED, BACKFILL PER SECTION B C-102. R&W (E) HATCHES FILL WITH CONCRETE. R&S (E) PUMPS; CLEAN AND RETURN PUMPS DIRECTLY TO PUBLIC WORKS WHEN (N) PUMPS ARE OPERATIONAL AND TESTED R&R (E) GENERATOR AND (E) PAD (E) A-AA-AAA JS - CHANNEL TO BE MODIFIED, SEE CIVIL SHEETS R&W (E) FORCE MAIN & ASSOCIATED CONDUIT/CABLING R&R (E) CG&S AS REQUIRED FOR CONSTRUCTION, SEE C-002 FOR (N) CG&S AND DRIVEWAY R&W (E) 12" SD. SEE YARD PIPING PLAN SHEET C-003 FOR (N) LINE LOCATION R&W (E) FORCE MAIN & ASSOCIATED CONDUIT/CABLING ABANDON (E) 14" SD BETWEEN (E) SDMH AND (E) JS (E) SSMH AAA R&W (E) SDMH R&W (E) 15" SS LINES (E) SSMH DATE STREET P STREET (E) W R&W WHEN REROUTED R&R (E) WATER METER AND BFP SEE CIVIL DRAWINGS PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 PROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 SITE DEMOLITION PLAN 15 CD-101 1" = 6'BDW PX BDW SHEET NOTES: 1. BYPASS PUMPING OR FLOW REROUTING IS REQUIRED TO EXECUTE MUCH OF THE WORK AND SHALL BE COORDINATED WITH THE DEMOLITION SEQUENCING. CONTRACTOR MUST MAINTAIN BYPASS PUMPING OPERATION FOR DURATION OF CONSTRUCTION UNTIL TIE-IN AND COMMISSIONING OF NEW FACILITIES IS COMPLETE. REFER TO SPECIFICATIONS 01500 FOR FURTHER REQUIREMENTS. 2. THE DRY PIT BENEATH THE ELECTRICAL CONTROLS BUILDING MUST BE ACCESSED TO ROUTE FLOWS DURING DEMOLITION & RECONSTRUCTION. CONFINED SPACE ENTRY PROCEDURES REQ'D. ONCE THE (N) WET WELL IS COMMISSIONED AND THE FLOW DIVERSION IS NO LONGER REQUIRED, CONTRACTOR SHALL SEAL OFF THE ENTRANCE TO THE DRY PIT - SEE STRUCTURAL DWGS. CONTRACTOR HAS OPTION TO SALVAGE ANY MATERIALS FROM THE DRY PIT FOR ITS OWN PURPOSES. 3. THE EXISTING ELECTRICAL CONTROLS BUILDING ROOF IS TO BE DEMOLISHED AND REPLACED. CONTRACTOR MAY USE VERTICAL ACCESS CREATED BY REMOVAL FOR ELECTRICAL AND CONTROLS INSTALL BUT SHALL PROTECT ALL EQUIPMENT. 4. CONTRACTOR SHALL PROVIDE SHEETING/SHORING AS NECESSARY TO MAINTAIN EXISTING FACILITIES. 5. UNLESS NOTED OTHERWISE ALL PIPING WITHIN THE PROJECT SITE THAT IS NOT USED FOR UPDATED STATION BUT OUTSIDE OF THE LIMITS OF NEW STRUCTURES TO BE R&W. GRAVITY PIPES SPECIFICALLY CALLED OUT AS "R&W OR ABANDON" MAY BE PLUGGED WITH CDF/GROUT. 6. IF ASBESTOS CEMENT PIPES (ACP) ARE ENCOUNTERED THE CONTRACTOR SHALL HALT WORK AND THE CITY AND ENGINEER SHALL BE NOTIFIED IMMEDIATELY. 7. EXISTING ELEVATIONS AND DIMENSIONS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM PRIOR TO COMMENCING ANY DEMOLITION WORK. 8. ALL EXISTING FACILITIES, PIPELINES, AND STRUCTURES NOT INDICATED IN SCOPE OF DEMOLITION DRAWINGS THAT ARE DAMAGED AND/OR REMOVED SHALL BE REPLACED TO EXISTING OR BETTER CONDITION AT THE CONTRACTOR'S EXPENSE. 9. PIPING BETWEEN MH AA0.1 AND (E) A-AA-AAA JS TO REMAIN IN PLACE UNTIL NEW WET WELL IS IN PLACE AND FLOW DIVERSION IS NO LONGER REQUIRED UNLESS ALTERNATIVE FLOW REROUTING/BYPASS PUMPING PLAN APPROVED. 10. TEMPORARY SS PIPING TO BE INSTALLED FOR FLOW BYPASS/ REROUTING (NOT SHOWN) MAY BE ABANDONED WITH CDF/GROUT. 11. EXISTING PIPING BETWEEN SSMH AA AND SSMH AA0.1, AND OUTSIDE OF THE LIMITS OF EXCAVATION FOR THE (N) WET WELL MAY BE ABANDONED IN PLACE BY FILLING WITH CDF/GROUT. 12. FOR PIPE PENETRATIONS INTO EXISTING DRY PIT OR WET WELL REMOVE PIPE TO NEAREST CONNECTION AND GROUT PENETRATION.

CD-102 DFLOW METERING DEMOLITION SCALE: NONE CD-102 FNOT USED SCALE: NONE CD-102 GNOT USED SCALE: NONE CD-102 AMETER MAIN DEMOLITION SCALE: NONE CD-102 BMCC DEMOLITION SCALE: NONE CD-102 HNOT USED SCALE: NONECD-102 ENOT USED SCALE: NONE CD-102 CCONTROLS DEMOLITION SCALE: NONE NOTES: DEMOLISH AND WASTE UTILITY METER MAIN. AND PAINT TO MATCH EXISTING BLOCK WALL. DEMOLITION TO TAKE PLACE AFTER CUT OVER TO NEW UTILITY SERVICE. PLUG ALL ANCHOR BOLT HOLES AND CONDUIT PENETRATIONS WITH NON-SHRINK GROUT NOTES: NOTES: NOTES: DEMOLISH AND WASTE MCC AND ATS. AND PAINT TO MATCH EXISTING BLOCK WALL. DEMOLITION TO TAKE PLACE AFTER CUT OVER TO NEW UTILITY SERVICE. PLUG ALL ANCHOR BOLT HOLES AND CONDUIT PENETRATIONS WITH NON-SHRINK GROUT DEMOLISH AND WASTE CONTROL PANEL AND LEVEL CONTROLS AND PAINT TO MATCH EXISTING BLOCK WALL. DEMOLITION TO TAKE PLACE AFTER NEW CONTROL SYSTEM CUT OVER AND TESTING. PLUG ALL ANCHOR BOLT HOLES AND CONDUIT PENETRATIONS WITH NON-SHRINK GROUT ANTENNA COAY AND CONDUIT TO BE PROTECTED AND REUSED. REFERENCE DWG E-101 LB TO BE PROTECTED AND REUSED. DEMOLISH AND WASTE FLOW TRANSMITTERS AND FLOW RECORDER PANELS. AND PAINT TO MATCH EXISTING BLOCK WALL. DEMOLITION TO TAKE PLACE PRIOR TO INSTALLATION OF NEW MCC. PLUG ALL ANCHOR BOLT HOLES AND CONDUIT PENETRATIONS WITH NON-SHRINK GROUT PROJECT SURVEYORPROJECT ENGINEER DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 212 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK MGB KB JP CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 CONTROLPOINT ENGINEERING SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 ELECTRICAL DEMOLITION CD-10216

DATE STREET P STREET S S S S S S S (E) SSMH AAA (E) WET WELL PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 NORTH ORIENTATION N DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 1 USA POTHOLES AND UTILITY INVERTS 5/12/2021 KFN FLOW DIVERSION PLAN 1 CD-20117 1" = 6' BDW PX BDW PROPOSED FLOW DIVERSION STEP 1. INSTALL TEMPORARY SUBMERSIBLE PUMP IN (E) WET WELL & ROUTE TEMPORARY PIPING TO CONNECT TO MANIFOLDING (EASTERN) FORCE MAIN. STEP 2. A. INSTALL LINE STOP ON MANIFOLDING FORCE MAIN AT TWO LOCATIONS: JUST OUTSIDE OF ELECTRICAL AND CONTROL BUILDING AND IN DATE STREET ON TREATMENT PLANT SIDE OF (N) FORCE MAIN. B. TIE TEMPORARY PIPE FROM WET WELL INTO MANIFOLDING FORCE MAIN DOWNSTREAM OF FLOW METER VAULT. PREVENT SPILLAGE, COLLECT WASTEWATER AND DISCHARGE TO WET WELL. BEGIN BYPASS PUMPING. CITY WILL DEACTIVATE & REACTIVATE (E) PUMP STATION AS REQ'D, COORDINATE ALL STEPS WITH CITY. (E) FLOW METER VAULT (E) GENERATOR PAD (E) ELECTRICAL & CONTROLS BUILDING STEP 1 STEP 2B (E) SSMH AA0.1 (E) SSMH AA0.2 (E) A-AA-AAA JS (E) SSMH A (E) SS A-LINE (E) SSMH AA (E) DRY PIT TEMPORARY PIPING (E) SS AAA-LINE NOTES: 1. ALL STEPS ARE CONCEPTUAL. WHILE LOCATIONS OF (E) INFRASTRUCTURE ARE GENERALLY TO SCALE, CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL STEPS TO BE COMPATIBLE W/ (E) & SUBSEQUENT SITE CONDITIONS. 2. CONTRACTOR MAY ASSUME FOR BIDDING PURPOSES THAT EXISTING FORCE MAIN PIPE IS CLASS 52 DIP. CONTRACTOR TO CONFIRM PIPE DIMENSIONS PRIOR TO SUBMITTING LINE STOP MATERIALS AND PROCEDURES. STEP 2A MANIFOLDING FORCE MAIN DEDICATED FORCE MAIN STEP 2A

DATE STREET P STREET S S S S S S S (E) SSMH AAA (E) WET WELL PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 NORTH ORIENTATION N DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 1 USA POTHOLES AND UTILITY INVERTS 5/12/2021 KFN FLOW DIVERSION PLAN 2 CD-20218 1" = 6' BDW PX BDW (E) FLOW METER VAULT STEP 4 STEP 4 (E) SSMH AA0.1 (E) SSMH AA0.2 (E) A-AA-AAA JS (E) SSMH A (E) SS A-LINE (E) SSMH AA TEMPORARY PIPING (N) FLOW METER VAULT BYPASS STUB-OUT PROPSED FLOW DIVERSION STEP 3. INSTALL LINE STOP ON DEDICATED (WESTERN) FORCE MAIN. STEP 4. R&W (E) FLOW METER VAULT AND (E) SSFM LINES IN AREA OF WET WELL EXCAVATION. PROVIDE BACKFLOW PREVENTION OR COLLECTION AND DISPOSAL ON DEDICATED (WESTERN) FORCE MAIN. STEP 5. INSTALL (N) FLOW METER VAULT. STEP 6. CONSTRUCT CONNECTION TO THE DEDICATED FORCE MAIN (WESTERN) LINE & INSTALL VALVES, BYPASS STUB-OUT AND PIPING WITHIN NEW FLOW METER VAULT AS SHOWN, WITH VALVE ON CROSSOVER IN CLOSED POSITION. STEP 6 INSTALL (N) PLUG VALVE IN CLOSED POSITION (E) SS AAA-LINE (E) GENERATOR PAD (E) ELECTRICAL & CONTROLS BUILDING (E) DRY PIT NOTES: 1. ALL STEPS ARE CONCEPTUAL. WHILE LOCATIONS OF (E) INFRASTRUCTURE ARE GENERALLY TO SCALE, CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL STEPS TO BE COMPATIBLE W/ (E) & SUBSEQUENT SITE CONDITIONS. 2. CONTRACTOR MAY ASSUME FOR BIDDING PURPOSES THAT EXISTING FORCE MAIN PIPE IS CLASS 52 DIP. CONTRACTOR TO CONFIRM PIPE DIMENSIONS PRIOR TO SUBMITTING LINE STOP MATERIALS AND PROCEDURES.STEP 3 STEP 5 STEP 6

DATE STREET P STREET S S S SS TEMP SSMH AA (N) SSMH AA0 S S S S (E) SSMH AAA (E) WET WELL PROJECT SURVEYOR SUBMITTAL % Date 30% DECEMBER 2020 60% JUNE 2021 95% SEPTEMBER 2021 100% NOVEMBER 2021 NORTH ORIENTATION N DESIGN BY DRAWN BY CHECK BY DATE SHEET IDENTIFICATION OF KSN PROJECT FILE NO. SHEET VERTICAL DATUM HORIZONTAL DATUM DRAWING SCALE 1"½"0 ORIGINAL DRAWING SCALE DATEDESCRIPTIONNO. APPR. www.ksninc.com 711 N. Pershing Avenue Stockton, CA 95203 209-946-0268 916-403-5900 1550 Harbor Blvd., Suite 210 West Sacramento, CA 95691 "P" STREET LIFT STATION UPDATE AND MODIFICATION CITY OF LIVE OAK CCS83, ZONE 2 NAVD88 NOVEMBER 2021 72 2449-0010 1 USA POTHOLES AND UTILITY INVERTS 5/12/2021 KFN FLOW DIVERSION PLAN 3 CD-20319 1" = 6' BDW PX BDW STEP 10B (E) SSMH AA0.1 (E) SSMH AA0.2 (E) A-AA-AAA JS (E) SSMH A (E) SS A-LINE R&R (E) SSMH AA TEMPORARY PIPING STEP 10C STEP 10C STEP 10C STEP 10D STEP 10D STEP 10C STEP 10A PROPOSED FLOW DIVERSION STEP 7. REROUTE AND CONNECT TEMPORARY BYPASS PIPING TO BYPASS STUBOUT. REMOVE INACTIVE TEMPORARY PIPING. STEP 8. R&W (E) GATE VALVE IN DRY PIT ON DEDICATED FORCE MAIN AND INSTALL BLIND FLANGE. REMOVE DEDICATE FORCE MAIN PIPING IN DRY PIT ON DISCHARGE SIDE TO WALL PENETRATION. STEP 9. CONNECT TEMPORARY PIPING TO MANIFOLDING FORCE MAIN. CITY WILL RE-ACTIVATE (E) PUMPS IN (E) WET WELL. REMOVE TEMPORARY PUMP AND PIPING FROM (E) WET WELL. STEP 10. DIVERT AA-LINE FLOWS (FROM SOUTHWEST) A. INSTALL TEMP SSMH AA-1. PUMP FLOWS FROM SSMH AA-1 TO SSMH AA0.1 OR (E) WET WELL. B. R&R SSMH AA. C. INSTALL NEW PIPELINE FROM SSMH AA TO SSMH AA0, INSTALL SSMH AA0, AND STUBOUT TOWARDS (N) A-AA JS TO BE CONSTRUCTED LATER. IF CULVERT OPTIONAL BID ITEM A IS INSTALLED, STUBOUT MUST BE INSTALLED PAST THE CULVERT LOCATION. OTHERWISE CONTRACTOR TO DETERMINE LENGTH OF STUBOUT. PLACE PLUG IN STUBOUT D. INSTALL TEMPORARY PIPING BETWEEN SSMH AA0 AND SSMH AA0.1 INCLUDING TEMP SSMH AA. STEP 11. REMOVE/ABANDON EXISTING 15" SS LINE THROUGH SITE. (N) FLOW METER VAULT BYPASS STUB-OUT (E) GENERATOR PAD (E) ELECTRICAL & CONTROLS BUILDING (E) DRY PIT (E) SS AAA-LINE TEMP

Official record

ArtifactSourceState
Agenda packetNot published in the sources we holdunavailable
BudgetNot published in the sources we holdunavailable
Action agendaNot published in the sources we holdunavailable
MinutesNot published in the sources we holdunavailable
Transcript or captionsNot published in the sources we holdunavailable
AttachmentNot published in the sources we holdunavailable

Official pages

Coverage and corrections

Records considered

  • Water, Sewer, and Storm Drain Committee

Not claimed by this page

  • Verified meeting decisions with item-specific public-source evidence
  • Item-level plain-language summaries are not available; this page does not infer individual agenda items.
  • Item-linked, attributed deliberation
  • A source-grounded next meeting date
  • A plain-English overview is not available.
  • Official outcomes have not been published.
  • A transcript is not available.
  • No audio or video recording is linked.
  • Speakers have not been reliably matched to public profiles.
  • Named people and places have not been reliably resolved.
  • An individual roll-call roster is not available.

No source correction or revision history is recorded for this meeting. A corrected artifact will appear here as a new version rather than replacing what is shown above.

Canonical record: affe48859f7d49e16cf3e2171b5b9e7b. This page changes as stronger artifacts are published; it never overwrites an agenda with minutes.

Publisher tools

Share or embed this record

POLISCOPE publisher tools

Share or embed this record