Enacted

Idaho authorizes single-stairway apartment buildings up to six stories with safety conditions

Original title: IDAHO BUILDING CODES – Adds to existing law to establish provisions regarding single stairway building exceptions.

Last action · April 2, 2026: Reported Signed by Governor on April 10, 2026 Session Law Chapter 320 Effective: 07/01/2026

Introduced
Committee
Floor Vote
Passed
Law

Track this bill to get notified when it advances a stage. One tap to stop, anytime.

Public stanceCommunity reactions are separate from the official record and reporting.

What This Bill Does

Local governments in Idaho are now authorized to allow apartment buildings of up to six stories to be served by a single interior stairway, provided specific fire safety, construction, and design standards are met. The law also revises local building code enforcement rules and takes effect on July 1, 2026.

Why it matters

Changes development standards for multi-family housing across Idaho cities and counties, affecting apartment design options, construction costs, and fire safety requirements for structures up to six stories.

Who It Affects

Groups the bill's text affects, as described in the record. Being affected is not a position for or against it.

Directly affected

residential group R-2 apartment building developers

Developers gain the option to construct apartment buildings up to six stories with a single stairway provided they meet detailed safety and construction specifications.

Directly affected

local governments

Local jurisdictions are authorized to permit single-stairway apartment buildings and must enforce the accompanying structural, fire, and safety mandates.

Key Facts

  • Local governments may allow residential group R-2 apartment buildings to be served by one single stairway if the building has no more than six stories above grade plane without an occupiable roof, or five stories with an occupiable roof and one basement level.
  • Single-stairway buildings are limited to no more than four dwelling units on any floor with a maximum gross floor area not exceeding 6,000 square feet per story.
  • Buildings utilizing a single stairway must install an automatic sprinkler system throughout in accordance with NFPA 13 standards.
  • Interior exit stairways and elevator shafts must have a fire resistance rating of not less than two hours.
Show all 8 facts
  • The width of the exit stairway must be at least 48 inches, and travel distance between the exit stairway and any dwelling unit entry door cannot exceed 20 feet.
  • An automatic smoke and fire detection system and compliant signage stating 'THIS BUILDING CONTAINS ONLY ONE STAIR' must be installed near the fire alarm control panel.
  • There can be no more than two single-exit buildings, or two single-exit areas in a single building, per lot.
  • The act takes effect as an emergency measure on July 1, 2026.

Frequently Asked Questions

What are the height and size limits for apartment buildings using a single stairway under this law?
Such buildings may have up to six stories above grade plane without an occupiable roof (or five stories with an occupiable roof and one basement level), with no more than four dwelling units per floor and a maximum gross floor area of 6,000 square feet per story.
Are fire sprinklers required in single-stairway apartment buildings?
Yes, an automatic sprinkler system must be provided throughout the building in accordance with standards.

What else do you want to know?

News Coverage

No news coverage found yet. Articles are indexed twice daily.

Where This Stands

Current status: Signed into law.

Procedural history

17 actions
  1. Apr 2, 2026Enrolled
    Reported Signed by Governor on April 10, 2026 Session Law Chapter 320 Effective: 07/01/2026
  2. Apr 2, 2026
    Delivered to Governor at 4:24 p.m. on April 2, 2026
  3. Apr 2, 2026
    Returned Signed by the President; Ordered Transmitted to Governor
  4. Apr 2, 2026
    Signed by President; returned to House
  5. Apr 2, 2026
    Received from the House enrolled/signed by Speaker
  6. Apr 2, 2026
    Reported Enrolled; Signed by Speaker; Transmitted to Senate
Show 11 earlier actions
  1. Apr 1, 2026Floor
    Returned from Senate Passed; to JRA for Enrolling
  2. Apr 1, 2026Floor
    Read third time in full – Rules Suspended (2/3 Vote - Read in full as required) – PASSED - 18-17-0 AYES – Bernt, Blaylock, Den Hartog, Foreman, Galloway, Hart, Kohl, Lenney, Nichols, Rabe, Ricks, Semmelroth, Shippy, Toews, VanOrden, Wintrow, Zito, Zuiderveld NAYS – Adams, Anthon, Bjerke(Bjerke), Burtenshaw, Carlson, Cook, Grow, Guthrie, Harris, Keyser, Lakey, Lent, Okuniewicz, Ruchti, Taylor, Ward-Engelking, Woodward Absent and excused – None Floor Sponsor - No sponsor data. Title apvd - to House
  3. Apr 1, 2026
    Reported out of Committee with Do Pass Recommendation; Filed for second reading
  4. Mar 30, 2026Committee
    Reported out of Committee and referred to: Local Government & Taxation
  5. Mar 25, 2026Introduced
    Introduced, read first time; referred to: Commerce & Human Resources
  6. Mar 25, 2026Floor
    Received from the House passed; filed for first reading
  7. Mar 24, 2026Floor
    Rules Suspended: Ayes 67 Nays 0 Abs/Excd 3, read in full as required – PASSED - 63-7-0 AYES – Alfieri, Barbieri, Beiswenger, Bingham, Boyle, Bruce, Burgoyne, Cannon, Cayler, Cheatum, Cornilles, Crane(12), Dygert, Egbert, Ehardt, Ehlers, Erickson, Fuhriman, Furniss, Galaviz, Gannon, Garner, Green, Hall(Stone), Handy, Harris, Hawkins, Haws, Healey, Hill, Holtzclaw, Hostetler, Leavitt, Manwaring, Marmon, Mathias, McCann, Mickelsen, Miller, Mitchell, Monks, Nelsen, Petzke, Pickett, Pohanka, Price, Rasor, Raybould, Raymond, Redman, Rubel, Sauter, Scott, Shepherd, Shirts, Tanner(13), Thompson, Vander Woude, Veile, Weber, Wheeler, Wisniewski, Mr. Speaker NAYS – Berch, Church, Crane(13), Mendive, Palmer, Skaug, Tanner(14) Absent – None Floor Sponsor - Redman Title apvd - to Senate
  8. Mar 24, 2026
    Read second time; Filed for Third Reading
  9. Mar 23, 2026
    Reported out of Committee with Do Pass Recommendation, Filed for Second Reading
  10. Feb 17, 2026Committee
    Reported Printed and Referred to Business
  11. Feb 16, 2026Introduced
    Introduced, read first time, referred to JRA for Printing

Version history

Only one version on file - nothing to compare yet. As later stages (committee substitute, engrossed, enrolled) are captured, the redline appears here.

View official text →

Lobbying Activity

No state lobbying filings in our records match this bill. Federal lobbying reports (LDA) cover Congress, so they are not listed on state bills.

Full breakdown

Who this bill affects and the strongest case for and against it, written only from the bill’s own text.

Connected Entities

BUSINESS COMMITTEE, International Building Code, International Code Council and 1 more
OrganizationBUSINESS COMMITTEE“House committee that introduced House Bill No. 706”Map →
OrganizationInternational Building Code“Building code standard referenced for apartment construction and safety rules”Map →
OrganizationInternational Code Council“Publisher of adopted building codes”Map →
OrganizationIdaho Building Code Board“Board responsible for adopting building codes and rules”Map →

Sources

Open source document

legislature.idaho.gov

Analysis Score

0–100
  • Significance75
    How much this matters to a regular citizen
  • Controversy30
    Intensity of disagreement among stakeholders
  • Entertainment5
    Compellingness for a non-policy-wonk reader
  • Buzz40
    Current news / social attention level

Publisher tools

Share or embed this record

POLISCOPE publisher tools

Share or embed this record