El Faro Duplexes Development Waiver Requests

Original title: El Faro Duplexes - Major Site Plan- Waiver to Major Site Plan in Review Project #2025080063 #33316 Parcel #13396-000-00 Michael W. Radcliffe Engineering, Inc. LDC 2.12.8 Current boundary and topographic survey CODE states Current boundary and topographic survey (one foot contour intervals extending 100 feet beyond the project boundary) based upon accepted vertical datum. Surveys will be less than 12 months old and accurately reflect current site conditions, meeting standards set forth in Ch. 5J-17 FAC. Alternate topographic data may be accepted if pre-approved by the Marion County Land Surveyor. APPLICANT requests waiver to use existing survey. Nothing has changed on vacant property with no improvements. Topo is still accurate. LDC 6.13.8.B(7) Stormwater conveyance criteria CODE states (7) Sizes. Stormwater conveyance pipes and cross culverts shall be a minimum of 18 inches diameter or equivalent. Driveway culverts shall be a minimum of 15 inches diameter or equivalent for residential use and a minimum of 18 inches diameter or equivalent for commercial use. Roof drains, prior to connection to the overall stormwater system, are exempt from minimum diameter requirements. APPLICANT requests a waiver to allow 15" pipe with supporting calculations. Flows are low and 15" is sufficient. LDC 6.13.7 Geotechnical criteria CODE states A. Methodology. The pattern and type of test borings shall be determined by the project engineer, geotechnical engineer, or geologist based on the project size, type, and complexity.(1)Infiltration/permeability rate tests shall follow methods acceptable to the governing State agency and shall be performed at the depth and location which will provide representative test results for use in the design of the retention/detention area. Soil identifications shall refer to the AASHTO Soil Classification System conforming to AASHTO Designation M 145-91. (2) Where visual reconnaissance, available published data, and/or initial borings suggest high karst sensitivity or lithologic variability, additional borings may be required if deemed necessary by the County Engineer or his designee. B. Minimum requirements. (1) Depth. Soil test borings shall be performed to a minimum depth of 10 feet below the proposed finished grade of the bottom of all retention/detention areas or the permanent pool elevation and once the data has been obtained the hole shall be backfilled and compacted. (2) Number of tests. At least two tests shall be performed within the boundary of each proposed retention/detention area. For each half acre of pond bottom area and for each lineal retention/detention area of 250 feet, an additional test shall be conducted. The County Engineer or his designee, may require additional tests if the initial tests indicate the need for them. (3) Infiltration/permeability tests. For retention/detention areas utilizing percolation or infiltration in the design model, there shall be a minimum of two infiltration rate tests for each retention/detention area. Data used for soil permeability testing or infiltration analyses for the retention/detention areas shall be signed and sealed by a professional engineer or professional geologist for both data and procedural accuracy. (4) Aquifer parameters. The estimated seasonal high ground water elevation and confining layer shall be clearly identified. C. Design considerations.(1)The estimated seasonal high water elevation and the confining layer shall be set no lower than the bottom of the boring for the purposes of stormwater system modeling.(2)The pond bottom elevation of a stormwater facility shall be designed a minimum of 1 foot above the estimated seasonal high water elevation. When the pond bottom is within 1 foot of the estimated seasonal high water elevation, a 50 percent reduction factor shall be used for percolation or ground water mounding analysis shall be included. APPLICANT request waiver to allow one boring to extend only 9' below DRA bottom. Two borings were taken and the remaining boring extends to required 10'. Borings are estimated and requested early in the process and sometimes final design doesn't exactly line up. Soils are sandy on this site. LDC 6.11.5.B, D Driveway width CODE states General Driveway Requirements. (1) Each buildable lot, parcel, or tract is entitled to a driveway unless cross access is available. (2) Adjacent properties under the same ownership shall be considered as a single property for application of driveway spacing or for driveway permits. Applicants may include a request that properties be considered individually for permitting purposes but the request must be specifically included in the permit and a sketch included that details the lot configurations and driveway placement. (3) Driveway location and minimum spacing shall be consistent with traffic safety standards. If standards cannot be achieved, the County Engineer or his designee can review and approve on a case-by-case basis. (4) Driveway width shall be subject to internal and external traffic flow considerations. The driveway width considerations include, but are not limited to, the number of lanes, the driveway geometrics, internal obstructions, and traffic safety. (5) Concrete mitered end sections are required for culverts when used for driveways accessing a roadway with posted speeds of 40 mph or greater. APPLICANT request - due to length of driveway and small property size, a 20' driveway is requested from NW Gainesville Road to the parking spaces where a 24" drive aisle is provided. The 20' width is adequate (local roads are 20" wide) while creating less impervious area and displacement in the FEMA zone. LDC 6.8.6 Buffers CODE states (2) B-Type buffer shall consist of a 20-foot wide landscape strip with a buffer wall. The buffer shall contain at least two shade trees and three accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 50 percent of the required buffer. APPLICANT requests waiver allow a 10' wide modified B buffer with opaque fence and same density of plantings on north asd west per Landscape plan by EDK/Ander Kesserling. Property to west is undeveloped. Property to north is zoned M-2 but has a single family residence more than 100' away. No buffer is required to the south. Along with the Type C buffer along the Gainesville Highway frontage this will provide adequate buffering for this small project. LDC 6.14.2.A & 6.14.2(C)(1)(a) Water connection requirement - Decentralized water system CODE states A. Connection determination. (1) All new and expanding development projects shall contact Marion County Utilities (MCU) for determination of availability and/or point of connection. Within ten working days, MCU shall issue an official written determination advising the applicant if services are available and, if so, shall indicate the potential source, the nearest connection point, and the need for any additional off-site facilities. Potential sources may include MCU, a Public Service Commission (PSC) certified utility, a city, a community development district, or other entity authorized by the State of Florida to provide water or wastewater services through its system. Developer shall include the written determination with all applications for building permits and/or other development reviews.(2) Connection distance determinations shall be measured beginning at the nearest property boundary and extend along any legal access eligible for utility installation and/or operation to available publicly served mains within the providing utility.(3)When property is within connection distance to water, the water main shall be extended to the farthest property line by Developer. Refer to Sec. 6.15.3.B for fire hydrant installation requirements. (4) When property is within connection distance to sewer:(a) Sewer main shall be extended by Developer to the closest point of service. (b) Sewer gravity main shall be extended by the Developer as directed by MCU. New residential development with 31 lots or more, all multi-family and commercial projects, shall design and construct a decentralized water system in compliance with the requirements of Division 6.14, and construct an on-site Water Treatment Plant (WTP) sufficient in size to serve the development in compliance with FDEP requirements and other applicable requirements of this Code. APPLICANT request waiver to utilize Dept. of Environmental Health Limited Use Water System. Project is outside of required MCU connection distance. Project is very small; only 12 duplex units and does not warrant expense of FDEP water system. The limited use water system, a type of decentralized system, is regulated by Dept. of Health and will provide sufficient supply and service. The project will tie into central water when available. LDC 6.14.2A & 6.14.2(C)(1)(a) Sewer connection requirement - Decentralized Sewer System CODE states A. Connection determination. (1) All new and expanding development projects shall contact Marion County Utilities (MCU) for determination of availability and/or point of connection. Within ten working days, MCU shall issue an official written determination advising the applicant if services are available and, if so, shall indicate the potential source, the nearest connection point, and the need for any additional off-site facilities. Potential sources may include MCU, a Public Service Commission (PSC) certified utility, a city, a community development district, or other entity authorized by the State of Florida to provide water or wastewater services through its system. Developer shall include the written determination with all applications for building permits and/or other development reviews.(2)Connection distance determinations shall be measured beginning at the nearest property boundary and extend along any legal access eligible for utility installation and/or operation to available publicly served mains within the providing utility.(3)When property is within connection distance to water, the water main shall be extended to the farthest property line by Developer. Refer to Sec. 6.15.3.B for fire hydrant installation requirements. (4) When property is within connection distance to sewer:(a) Sewer main shall be extended by Developer to the closest point of service. (b) Sewer gravity main shall be extended by the Developer as directed by MCU. New residential development with 31 lots or more, all multi-family and commercial projects, shall design and construct a decentralized water system in compliance with the requirements of Division 6.14, and construct an on-site Water Treatment Plant (WTP) sufficient in size to serve the development in compliance with FDEP requirements and other applicable requirements of this Code. APPLICANT requests to utilize FDEP permitted septic tanks with enhanced drainfields. Project is outside of required MCU connection distance. Project is very small; only 12 duplex units and does not warrant expense of FDEP Wastewater Treatment System. an enhanced septic drainfield system; now regulated by FDEP will provide adequate treatment and permittable service. The project will tie into central sewer when available.

Record date · December 15, 2025

Track this bill to get notified when it advances a stage. One tap to stop, anytime.

Public stanceCommunity reactions are separate from the official record and reporting.

What This Bill Does

The developer of the proposed El Faro Duplexes project is requesting seven specific waivers from Marion County land development codes. These requests cover site surveying, stormwater pipe sizing, soil testing, driveway width, landscaping buffers, and water/sewer connection requirements.

Why it matters

The approval of these waivers would allow the 12-unit duplex project to proceed with modified infrastructure and site design standards that deviate from standard county requirements.

Who It Affects

Groups the bill's text affects, as described in the record. Being affected is not a position for or against it.

Directly affected

El Faro Duplexes Developer

The developer is seeking approval for design and infrastructure deviations to proceed with the project.

Indirectly affected

Marion County Residents

Residents in the vicinity may be affected by changes to site drainage, landscaping, and utility infrastructure standards.

Key Facts

  • The project consists of 12 duplex units.
  • Applicant requests to use an existing boundary and topographic survey instead of a new one.
  • Applicant requests to use 15-inch stormwater pipes instead of the required 18-inch minimum.
  • Applicant requests to perform one soil boring to a depth of 9 feet instead of the required 10 feet.
Show all 8 facts
  • Applicant requests a 20-foot wide driveway instead of standard width requirements.
  • Applicant requests a 10-foot wide modified landscape buffer with an opaque fence instead of the required 20-foot wide B-Type buffer.
  • Applicant requests to use a Department of Health-regulated limited use water system instead of connecting to Marion County Utilities.
  • Applicant requests to use FDEP-permitted septic tanks with enhanced drainfields instead of connecting to central sewer.

Frequently Asked Questions

Why is the developer asking for these waivers?
The applicant states the project is small, the property has specific physical constraints, and the requested alternatives are sufficient for the project's needs.
Will the project connect to county water and sewer?
No, the applicant is requesting to use a limited use water system and septic tanks because the project is outside the required connection distance to Marion County Utilities.

What else do you want to know?

News Coverage

No news coverage found yet. Articles are indexed twice daily.

Full breakdown

Who this bill affects and the strongest case for and against it, written only from the bill’s own text.

Discoveries

1 pattern noticed across the record

Patterns POLISCOPE noticed across the record. These are observations to investigate, not conclusions.

policy shift90% confidence

Decentralized Utility Reliance

The applicant is citing the small scale of the project to bypass central utility connection requirements, relying instead on decentralized water and septic systems.

Sources

Open source document

webapi.legistar.com

Analysis Score

0–100
  • Significance40
    How much this matters to a regular citizen
  • Controversy20
    Intensity of disagreement among stakeholders
  • Entertainment5
    Compellingness for a non-policy-wonk reader
  • Buzz10
    Current news / social attention level

Publisher tools

Share or embed this record

POLISCOPE publisher tools

Share or embed this record